标准4-20ma电流检测设定上下限报警控制继电器开关模块RS485通讯
Link to the original- 100 — 1999 шт 5000$ per piece.
- 2000 — 50119 шт 4000$ per piece.
- 50120+ шт 3000$ per piece.
Inspection + photo report for $1.5.
We check the goods and take a photo report so you can make sure you get the right product without faults or damage
Delivery from China to Ukraine, Uzbekistan, European and African countries
Payable upon arrival at the warehouse in China
Returns are only possible while the item is in our warehouse in China. Once the goods have been dispatched from China, they cannot be returned
Photo and product description
1、产品使用说明视频连接文本屏显示实测电流和设置上下限https://v.youku.com/v_show/id_XMTQxNDU1NzIxNg==.html
如需特殊定制请联系客服!
二、接口说明:
输入端
正极:接供电电源正极
负极:接供电电源负极
A0:4-20ma信号输入
com:和电源负极是连接在一起的
D+:RS485接口信号
D-:RS485接口信号
输出端
NO:常开端
COM:公共端
NC:常闭端
三、产品标注
1、0~20ma电流检测接线图
四、产品功能
六种功能可设置如下:(在实时显示界面(非调节参数时)短按K3按键显示P-X调节模块)
P-1:超过设定值吸和,低于断开
测量值超过下限值继电器吸和,低于下限值吸和断开
P-2:超过设定值断开,低于吸和
测量值超过下限值继电器断开,低于下限值吸和吸和
P-3:区间内吸和,区间外断开
测量值在上限和下限值之间继电器吸和,否则断开
P-4:区间内断开,区间外吸和
测量值在上限和下限值之间继电器断开,否则吸和
P-5:低于下限断开,高于上限吸和
测量值超过下限值继电器断开,高于上限值继电器吸和
P-6:低于下限吸和,高于上限断开
测量值超过下限值继电器吸和,高于上限值继电器断开
五、设置说明
按键说明:
K1:移位选中要调节的数字
K2:按一下选中数字加1
K3:按一下选中数字减1/功能调节
按K1键第一下第一位闪烁,调节下限值十位,按K2,K3调节0~1变化
按K1键第二下第二位闪烁,调节下限值个位,按K2,K3调节0~9变化
按K1键第三下第三位闪烁,调节下限值小数点后1位,按K2,K3调节0~9变化
按K1键第四下第四位闪烁,调节上限值十位,按K2,K3调节0~1变化
按K1键第五下第五位闪烁,调节上限值个位,按K2,K3调节0~9变化
按K1键第六下第六位闪烁,调节上限值小数点后1位,按K2,K3调节0~9变化
按K1键第七下数码管不在闪烁,显示实测电流值
六、RS485 modbus_RTU协议说明(带RS485通讯的板子具有如下功能)
波特率:9600,8,N,1
模块默认地址 01
写寄存器功能码06
寄存器地址对应16进制
0x0000:下限值设定
0x0001:上限值设定
0x0002:模式设定
0x0008:设置模块地址
读寄存器功能码03
寄存器地址对应16进制
0x0000:读取下限设定值
0x0001:读取上限值
0x0002:读取当前模式
0x0003:读取实测电流值
eg1.设置下限设定值为发送
七、接线示例图
八、尺寸图
带外壳款如下图